Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. Fac. Odontol. Univ. Antioq ; 22(2): 153-163, jun. 2011. graf, tab
Article in Spanish | LILACS | ID: lil-598187

ABSTRACT

Introducción: el presente estudio pretendió determinar el comportamiento mecánico entre tramos protésicosrígidos y no rígidos de una prótesis fija de cinco unidades con pilar intermedio utilizando el análisis de elementos finitos (AEF) Métodos: se diseñó un modelo rígido de cinco unidades con 124,469 nodos y 76,215 elementos y un modelo no rígido con 125,130 nodos y 77,396 elementos, conformados por hueso esponjoso, hueso cortical, ligamento periodontal, pulpa, dentina,raíz, cemento resinoso, coronas metal-cerámica y ajuste tuve-lock (Sterngold®, Implamed Attleboro MA). El tramo protésico comprendió un incisivo central, un incisivo lateral, un canino, un primer premolar y un segundo premolar superior. Se aplicóuna fuerza de 200 N con dirección oblicua y vertical. Las variables incluidas en el modelado fueron módulo de elasticidad, razón de Poisson y el ajuste no rígido. Fueron calculados los esfuerzos von Misses, máximos principales y mínimos principalespara cada grupo. Resultados y conclusiones: el análisis del comportamiento mecánico indicó que en el tramo protésico rígidohubo mejor distribución de los esfuerzos en relación con el modelo no rígido. El comportamiento de cada grupo indicó que el modelo rígido transmitió menos esfuerzo a la raíz y al hueso subyacente. La influencia de poner un ajuste no se justificaría según los resultados de este estudio.


Introduction: the purpose of this study is to establish the mechanical behavior between rigid and non-rigid fixeddental prosthesis of five units with an intermediate abutment using the finite element analysis (FEA). Methods: a five unit rigid model with 124.469 nodes and 76.215 elements and a non-rigid model with 125.130 nodes and 77.396 elements were designed. It consisted of trabecular bone, cortical bone, periodontal ligament, pulp, dentine, root, resinous cement, metal ceramic crowns and tube-lock adjustment (Sterngold®, Implamed Attleboro MA). The fixed dental prosthesis included a central incisor, lateral incisor, canine, first and second upper premolars. A force of 200 N was applied with an oblique and vertical direction. The variables included in the model were modulus of elasticity, Poisson’s ratio and non-rigid adjustment. Von Misses stresses, main, maximum and minimum, were calculated for each group. Results and conclusions: the analysis of the mechanical behavior indicated that the rigid fixed dental prosthesis showed a better distribution of the stresses in comparison with the non-rigid model. The behaviorof each group indicated that the rigid model transmitted less stress to the underlying root and bone. The indication to use an adjustment would not be justified according to the results of this study.


Subject(s)
Biomechanical Phenomena , Dental Implantation
SELECTION OF CITATIONS
SEARCH DETAIL